WANTY PTA-ballonkateteret er et perifert ballonkateter over ledningen (OTW), specielt designet til perkutan transluminal angioplastik i aterosklerotiske obstruerede kar.
Den hydrofile belægning, som dækker den distale ende af kateteret, giver forbedret smøreevne til ballonskaftet.
A guidewire ({{0}}.014" 0.018" 0.035") is recommended for use with the Balloon Catheter (Balloon catheter specification refers to the attachment for detailed). The connector(s) at the end of hub provide two accuracy conical fittings with a 6 percent luer taper for securely fitted to other medicalequipment.
Intened use
WANTY PTA ballonkatetrene er indiceret til perifer transluminal angioplastik (PTA) til det perifere vaskulære system (inklusive iliaca arterie, femoral arterie, iliac femoral arterie, popliteal arterie og inferior genikulær arterie). Enheden er indiceret til at udvide den stenotiske vaskulære arterie til beregnet diameter til behandling af obstruktiv sygdom i perifere arterier.

Model specifikationer
Recommended guidewire0.035", double lumen catheter | ||||||||||
Catheter length(cm) | Balloon diameter (mm) | Balloon Length(mm) | ||||||||
20 | 40 | 60 | 80 | 100 | 120 | 150 | 200 | 220 | ||
80 | 3.00 | H080030002035D | H080030004035D | H080030006035D | H080030008035D | H080030010035D | H080030012035D | H080030015035D | - | - |
3.50 | H080035002035D | H080035004035D | H080035006035D | H080035008035D | H080035010035D | H080035012035D | H080035015035D | - | - | |
4.00 | H080040002035D | H080040004035D | H080040006035D | H080040008035D | H080040010035D | H080040012035D | H080040015035D | H080040020035D | H080040022035D | |
5.00 | H080050002035D | H080050004035D | H080050006035D | H080050008035D | H080050010035D | H080050012035D | H080050015035D | H080050020035D | H080050022035D | |
6.00 | H080060002035D | H080060004035D | H080060006035D | H080060008035D | H080060010035D | H080060012035D | H080060015035D | H080060020035D | H080060022035D | |
7.00 | H080070002035D | H080070004035D | H080070006035D | H080070008035D | H080070010035D | H080070012035D | H080070015035D | H080070020035D | H080070022035D | |
8.00 | H080080002035D | H080080004035D | H080080006035D | H080080008035D | - | - | - | - | - | |
9.00 | H080090002035D | H080090004035D | H080090006035D | H080090008035D | - | - | - | - | - | |
10.00 | H080100002035D | H080100004035D | - | - | - | - | - | - | - | |
12.00 | H080120002035D | H080120004035D | - | - | - | - | - | - | - | |
130 | 3.00 | H130030002035D | H130030004035D | H130030006035D | H130030008035D | H130030010035D | H130030012035D | H130030015035D | - | - |
3.50 | H130035002035D | H130035004035D | H130035006035D | H130035008035D | H130035010035D | H130035012035D | H130035015035D | - | - | |
4.00 | H130040002035D | H130040004035D | H130040006035D | H130040008035D | H130040010035D | H130040012035D | H130040015035D | H130040020035D | H130040022035D | |
5.00 | H130050002035D | H130050004035D | H130050006035D | H130050008035D | H130050010035D | H130050012035D | H130050015035D | H130050020035D | H130050022035D | |
6.00 | H130060002035D | H130060004035D | H130060006035D | H130060008035D | H130060010035D | H130060012035D | H130060015035D | H130060020035D | H130060022035D | |
7.00 | H130070002035D | H130070004035D | H130070006035D | H130070008035D | H130070010035D | H130070012035D | H130070015035D | H130070020035D | H130070022035D | |
8.00 | H130080002035D | H130080004035D | H130080006035D | H130080008035D | - | - | - | - | - | |
9.00 | H130090002035D | H130090004035D | H130090006035D | H130090008035D | - | - | - | - | - | |
10.00 | H130100002035D | H130100004035D | - | - | - | - | - | - | - | |
12.00 | H130120002035D | H130120004035D | - | - | - | - | - | - | - | |
Fælles modeller og specifikationer
Sygdom | PTA Balloon Catheter | Model Specifications |
Iliac artery stenosis | Common iliac artery:7-10mm; external iliac artery:5-8mm;Length: 40/60/80mm; Compatible guide wire: 0.035inch,Push rod length: 130cm; | fx:H130060008035 |
Femoropopliteal artery stenosis | Diameter 3-6mm; length 40-220mm; Compatible guide wire: {{0}}.035/0.018inch; push rod length: 130cm; | f.eks.:H130030015018,H130040015018 |
Inferior genicular artery stenosis | Diameter 1.5-4.0mm;conical balloon; length 20-220mm; Compatible guide wire:{{0}}.035/0.018inch; push rod length: 150/180cm; | f.eks.:H150020015014,H150025015014 |
central vein | Diameter: 6-12mm; Length: 40/60/80/100mm Compatible guide wire: 0.035inch; push rod length:130cm | f.eks.:H130100004035, H130120004035 |
TIPS | Diameter: 6/8 mm; Længde: 60/80 mm Compatible guide wire:0.035inch;push rod length:80cm | fx:H080060008035 |
Produktfordel
Ballonen foldes gennem opdelings- og rulleprocessen for at reducere det foldede tværsnitsareal-, ballonen er godt trukket tilbage og har hukommelse
Barty samarbejdede med jMedtech om at udvikle hydrofile belægningsformuleringer. Dobbelt-lagscoating er vedtaget for effektivt at reducere trombose og forbedre kateterpassabiliteten

KONTAKT INFORMATION
Navn: Eiffel lu
E-mail: Lllu@batymedical.com
Mobil: plus 86 182 2165 9426(whatsapp)
Populære tags: wanty 0.035'' otw pta balloon dilatation catheter, China, suppliers, manufacturers, factory, customized, OEM